Elsevier

Journal of Dentistry

Volume 18, Issue 4, August 1990, Pages 171-184
Journal of Dentistry

Review
Dose reduction in dental radiography

https://doi.org/10.1016/0300-5712(90)90106-OGet rights and content

Abstract

All exposures to ionizing radiation for medical and dental purposes carry risks to both the patient and staff. It is now accepted practice that all exposures should be kept as low as reasonably practicable to minimize these risks. The various methods currently available for dose limitation in intraoral and panoramic radiography and their effects on image quality are considered. In intraoral radiography the use of fast (E-speed) film and rectangular collimation offer dose reductions of approximately 50 per cent and 60 per cent respectively. Constant potential X-ray units, longer focus-to-skin distances and rare-earth filtration will permit further dose reductions. In panoramic radiography the radiation dose to the patients can be reduced by up to one-eighth by combining the use of constant potential X-ray units, rare-earth intensifying screens and rare-earth filtration.

References (117)

  • W.J. Girsch et al.

    An evaluation of Kodak Ektaspeed periapical film for use in endodontics

    J. Endodont.

    (1983)
  • A.D. Goren et al.

    Survey of radiologic practices among dental practitioners

    Oral Surg. Oral Med. Oral Pathol.

    (1989)
  • B.M. Gratt et al.

    Sensitometric characteristics of dental xeroradiography

    Oral Surg. Oral Med. Oral Pathol.

    (1983)
  • B.M. Gratt et al.

    Xeroradiography of dental structures. II. Image analysis

    Oral Surg. Oral Med. Oral Pathol.

    (1978)
  • B.M. Gratt et al.

    Imaging properties of intra-oral dental xeroradiography

    J. Am. Dent. Assoc.

    (1979)
  • B.M. Gratt et al.

    Xeroradiography for imaging biomaterials: a comparison with conventional radiography

    J. Prosthet. Dent

    (1980)
  • B.M. Gratt et al.

    An evaluation of rare-earth imaging systems in panoramic radiography

    Oral Surg. Oral Med. Oral Pathol.

    (1984)
  • B.M. Gratt et al.

    Frequency of artefacts with xeroradiography using artefactreduction techniques

    Oral Surg. Oral Med. Oral Pathol.

    (1986)
  • B.M. Gratt et al.

    A clinical comparison of xeroradiography and conventional film for the interpretation of periapical structures

    J. Endodont.

    (1986)
  • D.F. Greer

    Determination and analysis of absorbed dose resulting from various intra-oral radiographic techniques

    Oral Surg. Oral Med. Oral Pathol.

    (1972)
  • S.M. Hassen et al.

    A study of the zone of sharpness of three panoramic X-ray machines and the effect of screen speed on the sharpness zone

    Oral Surg. Oral Med. Oral Pathol.

    (1982)
  • C.E. Hurlburt et al.

    Rare-earth screens for panoramic radiography

    Oral Surg. Oral Med. Oral Pathol.

    (1984)
  • L.S. Jeromin et al.

    Xeroradiography for intra-oral dental radiology: a process description

    Oral Surg. Oral Med. Oral Pathol.

    (1980)
  • I. Kaffe et al.

    E-speed dental films processed with rapid chemistry. A comparison with D-speed film

    Oral Surg. Oral Med. Oral Pathol.

    (1987)
  • I. Kaffe et al.

    Densitometric evaluation of intra-oral X-ray films: Ektaspeed versus Ultraspeed

    Oral Surg. Oral Med. Oral Pathol.

    (1984)
  • S.F. Kapa et al.

    A clinical comparison of image quality and patient exposure reduction in panoramic radiography with heavy metal filtration

    Oral Surg. Oral Med. Oral Pathol.

    (1989)
  • L.T. Kircos et al.

    Exposure reduction of 96 per cent in intra-oral radiography

    J. Am. Dent. Assoc.

    (1986)
  • L.T. Kircos et al.

    Comparative evaluation of the sensitometric properties of screen-film systems and conventional dental receptors for intra-oral radiography

    Oral Surg. Oral Med. Oral Pathol.

    (1989)
  • S.L. Kogon et al.

    A clinical trial of a rare-earth screen/film system in a periapical cassette

    Oral Surg. Oral Med. Oral Pathol.

    (1984)
  • W.D. McDavid et al.

    The Intrex—a constant-potential X-ray unit for periapical dental radiography

    Oral Surg. Oral Med. Oral Pathol.

    (1982)
  • W.D. McDavid et al.

    Resolution of several screen-film combinations in rotational panoramic radiography

    Oral Surg. Oral Med. Oral Pathol.

    (1986)
  • S.R. Matteson et al.

    The effect of lesion size, restorative material and film speed on the detection of recurrent caries

    Oral Surg. Oral Med. Oral Pathol.

    (1989)
  • S. Mauriello et al.

    Clinical evaluation of a samarium/aluminium compound filter

    Oral Surg. Oral Med. Oral Pathol.

    (1989)
  • F. Mouyen et al.

    Presentation and physical evaluation of RadioVisoGraphy

    Oral Surg. Oral Med. Oral Pathol.

    (1989)
  • T. Okano et al.

    Effective exposure level and diagnostic performance in endodontic radiography

    Oral Surg. Oral Med. Oral Pathol.

    (1983)
  • T. Okano et al.

    Diagnostic accuracy on detection of proximal enamel lesions in nonscreen radiographic performance

    Oral Surg. Oral Med. Oral Pathol.

    (1985)
  • A.Z. Ponce et al.

    Use of E-speed film with added filtration

    Oral Surg. Oral Med. Oral Pathol.

    (1986)
  • A.Z. Ponce et al.

    Kodak T-Mat G film in rotational panoramic radiography

    Oral Surg. Oral Med. Oral Pathol.

    (1986)
  • A.Z. Ponce et al.

    The use of added erbium filtration in intra-oral radiography

    Oral Surg. Oral Med. Oral Pathol.

    (1988)
  • C. Price

    The effects of beam quality and optical density on image quality in dental radiography

    Oral Surg. Oral Med. Oral Pathol.

    (1986)
  • A.G. Richards et al.

    Reduction in dental X-ray exposures during the past 60 years

    J. Am. Dent. Assoc.

    (1981)
  • A.G. Richards et al.

    Samarium filtration in dental radiography

    Oral Surg. Oral Med. Oral Pathol.

    (1970)
  • R.G. Stephens et al.

    An investigation of potential applications of intensifying screens in intra-oral radiography

    Oral Surg. Oral Med. Oral Pathol.

    (1982)
  • K.H. Thunthy et al.

    Effect of mAs and kVp on resolution and on image contrast

    Oral Surg. Oral Med. Oral Pathol.

    (1978)
  • K.H. Thunthy et al.

    Sensitometric comparison of dental films of groups D and E

    Oral Surg. Oral Med. Oral Pathol.

    (1982)
  • K.H. Thunthy et al.

    Sensitometric and image analysis of T-grain film

    Oral Surg. Oral Med. Oral Pathol.

    (1986)
  • D.A. Tyndall

    Spectroscopic analysis and dosimetry of diagnostic X-ray beams filtered by rare-earth materials

    Oral Surg. Oral Med. Oral Pathol.

    (1986)
  • L.V. Arnold

    The Radiographic Detection of Initial Carious Lesions on the Proximal Surfaces of Teeth

  • J. Catandella-Fletcher

    A comparison of Ektaspeed and Ultraspeed films using manual and automatic processing solutions

    Oral Surg. Oral Med. Oral Pathol.

    (1987)
  • J.D. deWit et al.

    The influence of scattered radiation on the quality of intra-oral radiographs

    Dentomaxillofac. Radiol.

    (1986)
  • Cited by (35)

    • Radiation dose and protection in dentistry

      2010, Japanese Dental Science Review
      Citation Excerpt :

      Traditionally, round collimation is used for intraoral radiography. A circular collimation of 6 cm of diameter is approximately 135% larger in area than a conventional periapical dental film of size No. 2, indicating considerable scope for further collimation [67]. As rectangular collimator decreases the radiation dose by up to fivefold as compared with a short circular one [68–70], so radiographic equipment should equipped with rectangular collimation for periapical and bitewing radiographs [61].

    • Dental radiography technique and equipment: How they influence the radiation dose received at the level of the thyroid gland

      2007, Radiography
      Citation Excerpt :

      The phantom study proved a useful trial for detecting the radiation dose at the thyroid gland position and conclusively supported the use of the ‘low dose’ combination of the paralleling technique and rectangular collimator. Background research also identified that, despite evidential proof,4–6,8,14 the choice of the paralleling technique and rectangular collimator is not sufficiently integrated within dental practices. This investigation, in collaboration with others, identifies the need for more awareness concerning radiation hazards within dental practices, so that consequentially the application of radiation protection measures seem justifiable to the dentist or operator.

    • A quality assurance program in dental radiographic units in western Greece

      2005, Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology and Endodontology
      Citation Excerpt :

      Exposures times can be diminished by adopting either digital radiography or high-speed film.14 Rectangular collimation to the size of the film offers dose reduction.4,11,12 Replacement of mechanical timers with digital timers.23

    • The status of Spain's dental practices following the European Union directive concerning radiological installations

      2004, Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology and Endodontology
      Citation Excerpt :

      In Spain we have found no distributor selling rectangular collimators, which makes it extremely difficult for Spanish dentists to purchase such equipment. The official EU recommendations indicate that the use of a constant potential of 70 kVp, 8 mA, a 20-cm focal-skin distance, and filtration thickness of at least 1.5 mm Al results in considerable reduction in patient radiation exposure.1,15,34 According to the latest quality assurance reports in our study, 72.8% of Spanish dental installations comply with these recommendations.

    View all citing articles on Scopus
    View full text