@article {Brame5, author = {Jennifer L. Brame and Demah Salem AlGheithy and Enrique Platin and Shannon H. Mitchell}, title = {Use of a Self-Instructional Radiographic Anatomy Module for Dental Hygiene Faculty Calibration}, volume = {91}, number = {3}, pages = {5--13}, year = {2017}, publisher = {American Dental Hygienists{\textquoteright} Association}, abstract = {Purpose: Dental hygiene educators often provide inconsistent instruction in clinical settings and various attempts to address the lack of consistency have been reported in the literature. The purpose of this pilot study was to determine if the use of a use of a self-instructional, radiographic anatomy (SIRA) module improved DH faculty calibration regarding the identifica-tion of normal intraoral and extraoral radiographic anatomy and whether its effect could be sustained over a period of four months.Methods: A convenience sample consisting of all dental hygiene faculty members involved in clinical instruction (N=23) at the University of North Carolina (UNC) was invited to complete the four parts of this online pilot study: a pre-test, review of the SIRA module, an immediate post-test, and a four-month follow-up post-test. Descriptive analyses, the Friedman{\textquoteright}s ANOVA, and the exact form of the Wilcoxon-Signed-Rank test were used to an-alyze the data. Level of significance was set at 0.05. Participants who did not complete all parts of the study were omitted from data analysis comparing the pre to post-test performance.Results: The pre-test response rate was 73.9\% (N=17), and 88.2\% (N=15) of those initial participants completed both the immediate and follow-up post-tests. Faculty completing all parts of the study consisted of: 5 full-time faculty, 5 part-time faculty, and 5 graduate teaching assistants. The Friedman{\textquoteright}s ANOVA revealed no statistically significant difference (P=0.179) in percentages of correct responses between the three tests (pre, post and follow-up). The exact form of the Wilcoxon-Signed-Rank test revealed marginal significance when comparing percent of correct responses at pre-test and immediate post-test (P=0.054), and no statistically significant difference when comparing percent of correct responses at immediate post-test and the follow-up post-test four months later (P=0.106).Conclusions: Use of a SIRA module did not significantly affect DH faculty test performance. Lack of statistical significance in the percentages of correct responses between the three tests may have been affected by the small number of participants completing all four parts of the study (N=15). Additional research is needed to identify and improve methods for faculty calibration.}, issn = {1553-0205}, URL = {https://jdh.adha.org/content/91/3/5}, eprint = {https://jdh.adha.org/content/91/3/5.full.pdf}, journal = {American Dental Hygienists{\textquoteright} Association} }